Version 1.14 of 9th April 2008 | Bug-Fix for V13: channels are interchanged at high sampling rates very seldomly |
Version 1.13 of 27th February 2008 | Bug-Fix: M2i.70xx and M2i.72xx: when doing bit mode output (1, 2 or 4 bit) the system hangs. Bug came with version V12 |
Version 1.12 of 27th January 2008 | Bug-Fix: sometimes timeout when using very slow sampling rate (<< 100 kS/s)
|  | Bug-Fix: last bugs of oversampling mode eleminated
|  | Bug-Fix: trigger delay between synchronized cards |
Version 1.11 of 18th September 2007 | Lenght of continuous marker output (generator cards) increased. Is now 1/2 of memory size up to 255 samples
|  | Support of Extra FIFO polling mode added, single access to timestamp and ABA data
|  | Delay between cards of different type running with same speed reworked -> zero delay between cards now
|  | Bug-Fix: extremly seldom wrong data in timestamp FIFO starting with 0x80000000 |
Version 1.10 of 27th April 2007 | Output FIFO buffer size in hardware programmable to reduce latency on data change
|  | Bug-Fix: pulsewidth trigger for channels on module B didn't work properly all the time
|  | Bug-Fix: TTL trigger didn't work on settings with very small pre-trigger size
|  | Bug-Fix: very seldom channel data swapping on output cards
|  | Data timing improved |
Version 1.09 of 20th December 2006 | internal use only |
Version 1.08 of 1st December 2006 | Support of new Star-Hub hardware version V2
|  | Bug-Fix: trigger delay on modules with 4 or 8 analog channels fixed
|  | Bug-Fix: some star-hub trigger combination didn't work properly |
Version 1.07 of 30th October 2006 | Support of Star-Hub option added
|  | Bug-Fix: Force trigger sometimes didn't work on slow sampling rates |
Version 1.06 of 30th August 2006 | Support of output modes added
|  | Support of bit modes (7005) added |
Version 1.05 of 18th July 2006 | Bug-Fix: force trigger didn't work with very slow sampling clocks
|  | Trigger output can be programmed at Multiple Recording to either output one large trigger signal or one trigger pulse on every segment trigger
|  | Bug-Fix: some timing problems between base card and module solved |
Version 1.04 of 6th July 2006 | Support of digital cards added
|  | Force trigger now emerges single trigger events for Multiple Recording
|  | Support of 2 GByte and 4 GByte memory finished |
Version 1.03 of 27th June 2006 | BaseXIO option added to firmware including asynchronous I/O, additional trigger, timestamp reference clock and additonal timestamp inputs. This option needs to be ordered seperately
|  | Bug-Fix for Multiple Recording Mode/Gated Sampling mode: some trigger events not detected |
Version 1.02 of 1st June 2006 | Bug-Fix: card didn't start properly when sampling rate below 400 kS/s
|  | Added some functionality for M2i.31xx series
|  | Bug-Fix: Timestamp counter stopped between acquistions |
Version 1.01 of 10th April 2006 | first version delivered to customers |
|
| |
|
|