- 16 bit A/D converter board
- 16 synchronous channels with seperate A/D
- Maximum sampling rate 250 kS/s on 16 channels
- Extremely high dynamic range
- PCI Express x1 Interface
- compatible to x1, x4, x8, x16 slots
- 2.5 GBit/s burst transfer rate
- Up to 2 GSample memory
- 8 input ranges between ±50 mV and ±10 V
- Window/pulse width/re-arm/OR/AND trigger
- Automatic offset calibration
- Synchronisation to multi-board system possible
- Synchronous digital channels and ABA mode available as an option
M2i - new generation of PC instrumentsThe new M2i card series generation is the successor of the former MI series. The M2i series offers some outstanding features:  | Completely new developed base card
|  | 4 GByte memory with one slot width
|  | Optimized low jitter clock section
|  | Multi, Gate, ABA with programmable pre, posttrigger and timestamp
|  | Zero phase delay synchronization
|  | AND/OR conjunction of trigger/gate |

M2i.47xx FamilyThe M2i.47xx series allows recording of one, two, four, eight or sixteen channels with sampling rates of 100 kS/s up to 500 kS/s. These cards offer outstanding A/D features both in resolution and speed for PCI/PCI-X. They are available in several versions and different speed grades making it possible for the user to find an individual solution. The installed memory of up to 2 GSample can be used for fast data recording or sustained data streaming. The enhanced FIFO engine is capable of streaming even 16 channels with 500 kS/s sustained to memory or hard disk. PCI/PCI-X | PCI Express | 1 channel | 2 channels | 4 channels | 8 channels | 16 channels | | | 100 kS/s | 100 kS/s | 100 kS/s | 100 kS/s | | | | 100 kS/s | 100 kS/s | 100 kS/s | 100 kS/s | 100 kS/s | | | 250 kS/s | 250 kS/s | 250 kS/s | 250 kS/s | | | | 250 kS/s | 250 kS/s | 250 kS/s | 250 kS/s | 250 kS/s | | | 500 kS/s | 500 kS/s | 500 kS/s | 500 kS/s | | | | 500 kS/s | 500 kS/s | 500 kS/s | 500 kS/s | 500 kS/s |

Block diagramMemory | Ringbuffer: Recording with Pre- and Posttrigger [ more...] |
 | FIFO Modus: continuous data transfer up to 225 MB/s [ more...] |
 | Standard memory 128 MSamples |
 | Option memory upgrade to 256 MS, 512 MS, 1 GS or 2 GS on-board memory |
Trigger | Channel Trigger: Recognition of level and edge [ more...] |
 | Window Trigger: Trigger at window enter or leave [ more...] |
 | Pulsewidth Trigger: Trigger on defined pulsewidth [ more...] |
 | OR/AND Conjunction: Combine several trigger sources with OR and/or AND [ more...] |
 | Steepness trigger between two levels [ more...] |
 | External Trigger: Input or output of external TTL signal [ more...] |
 | Option Multiple Recording: Recording of trigger events with high repetition rates and very small dead time [ more...] |
 | Option Gated Sampling: Recording controlled by gate signal [ more...] |
 | ABA mode (dual timebase): combination of slow continuous recording with fast acquisitions on trigger [ more...] |
 | Option Timestamp: Timestamps for trigger events [ more...] |
Clock | External Clock: Input or output of sampling clock [ more...] |
 | Reference Clock: Used to generate sampling clock [ more...] |
Extras | Option Star-Hub: Synchronisation of up to 16 boards with no phase delay [ mehr...] |
 | Option BaseXIO: 8 asynchronous digital I/O, 2 extra trigger, Timestamp refclock [ more...] |
Software Support | Standard drivers for Windows and Linux as well as examples for C/C++, Delphi and Basic are included in the delivery [ more...] |
 | SBench: Comfortable measurement software for windows [ more...] |
 | SPviewIT: comfortable and fast hard disk streaming software for Windows [ mehr...] |
 | Option LabVIEW drivers: Libraries and examples for LabVIEW[ more...] |
 | Option DASYLab driver: Direct access to cards with DASYLab [ more...] |
 | Option MATLAB driver: Universal driver for all cards [ more...] |
 | Option VEE driver: Libraries and examples for Agilent VEE [ more...] |
DownloadsApplication Notes
|